Standard Test Method for Extracting Residue from Metallic Medical Components and Quantifying via Gravimetric Analysis
Automatische name übersetzung:
Standard Test Method for Extrahieren Rückstand aus metallischen medizinischen Komponenten und Quantifizierung über gravimetrische Analyse
NORM herausgegeben am 1.3.2012
Bezeichnung normen: ASTM F2459-12
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.3.2012
SKU: NS-53920
Zahl der Seiten: 7
Gewicht ca.: 21 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
extractable residue, gravimetric analysis, metallic medical components, non-soluble extractables, non-soluble debris, water soluble extractables, Gravimetric determination, Medical devices/equipment, Quantitative analysis/measurement, Residue, Water-soluble extractable residue, ICS Number Code 11.100.99 (Other standards related to laboratory medicine)
Significance and Use | ||||||||||
This test method is suitable for determination of the extractable residue in metallic medical components. Extractable residue includes aqueous and non-aqueous residue, as well as non-soluble residue. This test method recommends the use of a sonication technique to extract residue from the medical component. Other techniques, such as solvent reflux extraction, could be used but have been shown to be less efficient in some tests, as discussed in X1.2. This test method is not applicable for evaluating the extractable residue for the reuse of a single-use component (SUD). |
||||||||||
1. Scope | ||||||||||
1.1 This test method covers the quantitative assessment of the amount of residue obtained from metallic medical components when extracted with aqueous or organic solvents. 1.2 This test method does not advocate an acceptable level of cleanliness. It identifies one technique to quantify extractable residue on metallic medical components. In addition, it is recognized that this test method may not be the only method to determine and quantify extractables. 1.3 Although these methods may give the investigator a means to compare the relative levels of component cleanliness, it is recognized that some forms of component residue may not be accounted for by these methods. 1.4 The applicability of these general gravimetric methods have been demonstrated by many literature reports; however, the specific suitability for applications to all-metal medical components will be validated by an Interlaboratory Study (ILS) conducted according to Practice E691. 1.5 This test method is not intended to evaluate the residue level in medical components that have been cleaned for reuse. This test method is also not intended to extract residue for use in biocompatibility testing. Note 1—For extraction of samples intended for the biological evaluation of devices or materials, refer to ISO 10993–12. 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7 This standard may involve hazardous or environmentally-restricted materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historisch
1.2.2013
Historisch
15.10.2010
Historisch
1.12.2011
Historisch
1.4.2012
Historisch
1.3.2011
Historisch
1.3.2014
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-04 (Zahl der Positionen: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.