Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Determining the Protective Performance of an Arc Protective Blanket for Electric Arc Hazards
Automatische name übersetzung:
Standard Test Methode zur Bestimmung der Schutzwirkung eines Arc-Schutzdecken für Lichtbogengefahren
NORM herausgegeben am 1.5.2009
Bezeichnung normen: ASTM F2676-09
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.5.2009
SKU: NS-54355
Zahl der Seiten: 7
Gewicht ca.: 21 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
arc blast, arc flash, arc flash protection, arc protective blankets, arc rating, blanket, breakopen threshold performance, electrical arc protection, ICS Number Code 13.340.99 (Other protective equipment)
Significance and Use | ||||
This test method determines the effectiveness of arc protective blankets in suprressing the combined effects of an arc flash and arc blast. The arc exposure energy is produced from controlled phase-to-ground arc fault. The resulting arc flash and blast energy are intentionally directed onto the test specimen to simulate worst case conditions. Test results will describe the maximum arc current and product of arc current and cycles at which test specimens block the energy without breakopen, ability to self-extinguish afterflaming, afterflame time and the detection of mechanical attachment failures during testing. Mechanical attachment failure and afterflame time are obtained from visual observations and video recording after each arc exposure. This test method maintains the arc protective blanket in a vertical position and does not involve movement except that resulting from the arc exposure. In this test method, test specimens are exposed at three arc current levels to determine the test specimen’s performance. Note 2—In experimental testing, some blankets increase in protection (in value of kA*cycles to cause breakopen) as the arc current increases and some decrease as shown in Fig. 1. This test method is designed to recognize this behavior and to specify testing over the range of arc current levels including lower levels of 5 kA or 10 kA, or both. This test method specifies a standard set of exposure conditions. Different exposure conditions may produce different results. Note 3—In addition to the standard set of exposure conditions, it is permitted to test using other conditions representative of the expected hazard, reported all non-standard test conditions that are used.
|
||||
1. Scope | ||||
1.1 This test method is used to evaluate the ability of the arc protective blankets to withstand the effects of arc flash and arc blast in a configuration in which the blanket is hung or anchored near energized equipment. Specifically, this test method is used to determine the arc protective blanket’s (1) resistance to breakopen, (2) mechanical strength, and (3) ability to self-extinguish flames following a controlled arc exposure. 1.2 This method is used to determine the performance of arc protective blankets in terms of: maximum arc current level expressed in kA and BTP (BTP) expressed as the product of arc current in kA and arc duration in number of cycles to cause breakopen (kA*cycles). Cycles are on the basis of 60 Hz. 1.3 Blanket test specimens used in this test method are test size blankets of 152 ± 5 cm (60 ± 2 in.) by 122 ± 5 cm (48 ± 2 in.). The test specimen size is for testing purposes only. Commercially available arc protective blankets either larger or smaller than the test specimen size are covered by this standard. 1.4 The arc protective blankets described in this test method are made of flame-resistant materials and are available in varying sizes and configurations based on the application. 1.5 This test method shall be used to measure and describe the properties of materials, products, or assemblies in response to incident thermal (convective and radiant) and pressure energies generated by an electric arc under controlled laboratory conditions. 1.6 The values stated in SI units shall be regarded as standard. The values given in parentheses are mathematical conversion to inch-pound or other units commonly used for arc testing. 1.7 This standard shall not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire assessment, which takes into account all of the factors, which are pertinent to an assessment of the fire hazard of a particular end use. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautions, see Section 7. |
||||
2. Referenced Documents | ||||
|
Historisch
1.5.2010
Historisch
1.3.2014
Historisch
1.3.2014
Historisch
1.3.2014
Historisch
1.6.2007
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-22 (Zahl der Positionen: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.