Standard Practice for Evaluating Mobile Bearing Knee Tibial Baseplate Rotational Stops
Automatische name übersetzung:
Standard Praxis zur Beurteilung von Mobil Bearing Knee Tibiabasisplatte Drehanschläge
NORM herausgegeben am 15.1.2015
Bezeichnung normen: ASTM F2722-15
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 15.1.2015
SKU: NS-581161
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
ICS Number Code 11.040.40 (Implants for surgery, prothetics and orthotics)
Significance and Use | ||||
4.1 Fundamental aspects of this practice include the use of dynamic rotational force and motion representative of the human knee joint during an activity of daily living (deep flexion) and the effect of these forces and motions on the design features which stop or limit rotation in a mobile bearing knee design. 4.2 This test is required if rotational stops are designed to limit motion to ±20° or less; or there are other resistances to rotational motion with this ±20° range. In some instances, the rotational displacement could occur in both the inferior and superior interfaces. |
||||
1. Scope | ||||
1.1 This practice covers a laboratory-based in vitro method for evaluating the mechanical performance of materials and devices being considered for replacement of the tibio-femoral joint in human knee joint replacement prostheses in mobile bearing knee systems. 1.2 Mobile bearing knee systems permit internal external rotation to take place on one or both articulating surfaces. Some designs place physical limits or stops to the amount of rotation. Other designs may have increases of a resistance force with increases in rotation. 1.3 Although the methodology describes attempts to identify physiologically relevant motions and force conditions, the interpretation of results is limited to an 1.4 This practice is only applicable to mobile knee tibial systems with a rotational stop. 1.5 The values stated in SI units are regarded as standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||
2. Referenced Documents | ||||
|
Historisch
1.5.2008
Historisch
1.3.2014
Historisch
15.2.2012
Historisch
1.12.2011
Historisch
1.12.2011
Historisch
1.10.2014
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-01-08 (Zahl der Positionen: 2 218 384)
© Copyright 2025 NORMSERVIS s.r.o.