Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Analysis of Heavy Metals in Glass by Field Portable X-Ray Fluorescence (XRF)
Automatische name übersetzung:
Standard Test Method for Analyse der Schwermetalle in Glas von Feld tragbare Röntgenfluoreszenz (RFA)
NORM herausgegeben am 15.2.2013
Bezeichnung normen: ASTM F2980-13
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 15.2.2013
SKU: NS-54811
Zahl der Seiten: 9
Gewicht ca.: 27 g (0.06 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
EDXRF, energy dispersive, glass, X-ray, X-ray fluorescence, XRF, ICS Number Code 81.040.10 (Raw materials and raw glass)
Significance and Use | ||||||||||||||||||||||||
5.1 Waste glass is currently recycled into various consumer products. This test method has been developed as a tool for evaluation of heavy metals in glass to satisfy reporting requirements for maximum allowable content for some applications. 5.2 The ranges within which this test method is quantitative are given in Table 1. 5.3 For amounts of the analyte elements outside the ranges in Table 1, this test method provides screening results. That is, it provides an unambiguous indication that each element can be described as present in an amount greater than the scope upper limit or that the amount of the element can be described as less than the scope lower limit with a high degree of confidence. 5.4 These methods can be applied to
glass beads, plate glass, float glass, fiber glass, or ground
glass. This test method has been validated for the ranges of matrix
compositions that are summarized in Table 2.
5.5 Detection limits, sensitivity, and element ranges will vary with matrices, detector type, and other instrument conditions and parameters. 5.6 All analytes are determined as the element and reported as such. These include all elements listed in 1.1 This test method covers field portable X-ray fluorescence (XRF) spectrometric procedures for analyses of arsenic and lead in glass compositions using field portable energy dispersive XRF spectrometers. 1.2 The mass fraction range of arsenic within which this test method is quantitative is given in 1.3 The mass fraction range for which lead was tested is given in Table 1. However, lead results cannot be considered quantitative on the basis of single-sample results because the precision performance is not good enough to allow laboratories to compare results in a quantitative manner. 1.3.1 To obtain quantitative
performance, lead results must consist of the average of four or
more determinations.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in Section 7 on Hazards. |
||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||
|
Historisch
1.4.2010
Historisch
1.3.2012
Historisch
1.5.2014
Historisch
1.1.2010
Historisch
1.8.2013
Historisch
15.6.2012
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-22 (Zahl der Positionen: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.