Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Specification for Ball Drop Impact Resistance of Laminated Architectural Flat Glazing
Automatische name übersetzung:
Standard-Spezifikation für Ball Drop Schlagfestigkeit des Verbund Architectural Glazing Wohnung
NORM herausgegeben am 1.8.2013
Bezeichnung normen: ASTM F3006-13
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.8.2013
SKU: NS-54850
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
annealed glass, architectural flat glass, ball drop, chemically strengthened glass, flat glass, fragmentation, heat strengthened glass, laminated glass, plastic sheeting, plastics, retention, safety glass, safety glazing, tempered glass, ICS Number Code 81.040.20 (Glass in building)
1. Scope | ||||||||||||||||||||||
1.1 This specification covers the destructive ball drop testing of laminated flat glass products intended for use in architectural glazing applications. 1.2 This specification is intended for use as an in-plant quality control test to evaluate the impact performance of laminated flat glass when a 2.3 kg, 83 mm diameter smooth solid steel ball is dropped from a specified height. 1.3 This specification does not yield data that is a substitute for safety glazing test requirements of ANSI Z97.1 or CPSC 16 CFR 1201. Qualification under this specification provides a basis for judgment of the ability of specimens to withstand the appropriate shot-bag impact. This specification provides a mechanism to allow fabricators a less cumbersome and lower cost method for the evaluation of impact performance that may be performed on a frequent basis while reducing the amount of waste materials generated from traditional impact tests. 1.4 This specification is applicable to symmetrical and asymmetrical annealed, heat-strengthened, chemically strengthened, fully tempered laminated architectural flat glass including but not limited to: float, patterned, sheet, sand-blasted, grooved, and fritted. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in Section 4 on Hazards. |
||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||
|
Historisch
1.12.2012
Historisch
1.10.2010
Historisch
1.3.2010
Historisch
1.10.2011
Historisch
1.3.2012
Historisch
1.6.2012
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-03 (Zahl der Positionen: 2 209 203)
© Copyright 2024 NORMSERVIS s.r.o.