Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Methods for Measuring Pull Strength of Microelectronic Wire Bonds (Includes all amendments And changes 8/16/2017).
Automatische name übersetzung:
Standard-Prüfverfahren für Mess Zugfestigkeit von Mikrodrahtverbindungen
NORM herausgegeben am 1.1.2001
Bezeichnung normen: ASTM F459-84(1995)e1
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2001
SKU: NS-55379
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
pull strength of microelectronic wire bonds, aluminum ultra-sonic wedge bonds, aluminum ball bonds, gold wedge bonds, ball bonds, wire bonds
1. Scope | ||
1.1 These test methods cover tests to determine the pull strength of a series of wire bonds. Instructions are provided to modify the methods for use as a referee method. The methods can be used for wire bonds made with wire having a diameter of from 0.0007 to 0.003 in. (18 to 76 m). Note 1--Common usage at the present time considers the term "wire bond" to include the entire interconnection: both welds and the intervening wire span. 1.2 These test methods can be used only when the loop height of the wire bond is large enough to allow a suitable hook for pulling (see Fig. 1 ) to be placed under the wire. 1.3 The precision of these methods has been evaluated for aluminum ultra-sonic wedge bonds; however, these methods can be used for aluminum ball bonds and gold wedge or ball bonds, as aluminum wedge bonds are the most sensitive to manufacturing variations (such as bond deformation) of any wire-bond type. 1.4 These methods are destructive. They are appropriate for use in process development or, with a proper sampling plan, for process control or quality assurance. 1.5 A nondestructive procedure is described in Practice F458. 1.6 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
2. Referenced Documents | ||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-10-31 (Zahl der Positionen: 2 208 647)
© Copyright 2024 NORMSERVIS s.r.o.