Test Methods for Measuring Beam Divergence of Pulsed Lasers by the Apertured-Detector Technique (Withdrawn 2001)
Automatische name übersetzung:
Prüfverfahren zur Bestimmung der Strahldivergenz gepulster Laser durch die Öffnungen versehene - Detector -Technik (Withdrawn 2001)
NORM herausgegeben am 1.1.1992
Bezeichnung normen: ASTM F524-77(1992)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.1992
SKU: NS-55616
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
Aperture-detector technique, Double detector method, Single detector method, beam divergence of pulsed lasers,, Beam divergence, pulsed lasers, by apertured-detector technique,, Divergence, pulsed laser beams, by apertured-detector technique,, Lasers and laser applications, beam divergence (of pulsed lasers), by aperture-detector technique,, Threshold detectors, pulsed lasers, for measuring beam divergence, ICS Number Code 31.260 (Optoelectronics. Laser equipment)
1. Scope |
1.1 These test methods cover the determination of the percentage of total beam energy contained in a given far-field divergence angle, without requiring the use of calibrated energy detectors. The methods make use of an apertured-detector technique. 1.2 These test methods apply to pulsed lasers in which the output polarization characteristics do not vary between successive pulses. 1.3 A single-detector method is used when the variation in energy from shot to shot of the laser under test is less than or equal to a value agreed upon by the parties to the test. 1.4 A double-detector method is used when the variation in energy from shot to shot of the laser under test exceeds a value agreed upon by the parties to the test. 1.5 The reported precision applies to lasers with cylindrically symmetric beam energy-density distributions. Deviation of the beam from cylindrical symmetry may decrease the precision of the test methods. 1.6 The appropriate test method may be applied for a given laser at a number of divergence angles and a relative beam-energy profile derived. 1.7 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For hazard statement, see Section 9. |
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-10-29 (Zahl der Positionen: 2 206 160)
© Copyright 2024 NORMSERVIS s.r.o.