Standard Specification for Ultra-High-Molecular-Weight Polyethylene Powder and Fabricated Form for Surgical Implants
Name übersetzen
NORM herausgegeben am 1.4.2021
Bezeichnung normen: ASTM F648-21
Ausgabedatum normen: 1.4.2021
SKU: NS-1023160
Zahl der Seiten: 9
Gewicht ca.: 27 g (0.06 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Implants for surgery, prosthetics and orthoticsThermoplastic materials
This specification covers ultra-high-molecular-weight polyethylene (UHMWPE) powder and fabricated forms for use in surgical implants. UHMWPE powder shall be of virgin polymer manufactured from a homopolymer of ethylene, while the fabricated forms shall be manufactured from the same UHMWPE powder without any stabilizers or processing aids. Tests for viscosity number, elongation stress, ash content, extraneous matter, and trace elements shall be performed for UHMWPE powders, while tests for density, ash content, tensile strength, yield strength, elongation, and impact strength shall be performed for fabricated forms. All tests shall conform to the requirements specified.
Keywords:
fabricated forms, powdered form, ultra-high molecular weight polyethylene ,, ICS Number Code 11.040.40 (Implants for surgery, prothetics and orthotics),83.080.20 (Thermoplastic materials)
1. Scope | ||||||||||||||||||||||||||||||||
1.1?This specification covers ultra-high molecular weight polyethylene powder (UHMWPE) and fabricated forms intended for use in surgical implants. 1.2?The requirements of this specification apply to UHMWPE in two forms. One is virgin polymer powder (Section 4). The second is any form fabricated from this powder from which a finished product is subsequently produced (Section 5). This specification addresses material characteristics and does not apply to the packaged and sterilized finished implant. 1.3?The requirements of this specification do not apply to UHMWPE virgin powder or fabricated forms intentionally crosslinked or blended with other additives, for example, antioxidants. 1.4?The biological response to polyethylene in soft tissue and bone has been well characterized by a history of clinical use (1-3)2 and by laboratory studies 1.5?The values stated in SI units are to be regarded as standard. 1.6?The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-22 (Zahl der Positionen: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.