Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Practice for Use of a Cellulose Triacetate Dosimetry System
Automatische name übersetzung:
Standard Praxis zur Verwendung eines Cellulosetriacetat Dosimetriesystem
NORM herausgegeben am 1.6.2012
Bezeichnung normen: ASTM/ISO 51650-13
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.6.2012
SKU: NS-902
Zahl der Seiten: 6
Gewicht ca.: 18 g (0.04 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
absorbed dose, cellulose triacetate, CTA, dose, dosimeter, dosimetry system, electron beam, gamma radiation, ionizing radiation, irradiation, radiation, radiation processing, radiation sterilization, ICS Number Code 17.240 (Radiation measurements)
Significance and Use |
The CTA dosimetry system provides a means for measuring absorbed dose based on a change in optical absorbance in the CTA dosimeter following exposure to ionizing radiation (5, 7-14). CTA dosimetry systems are commonly used in industrial radiation processing, for example in the modification of polymers and sterilization of health care products. CTA dosimeter film is particularly useful in absorbed dose mapping because it is available in a strip format and if measured using a strip measurement device, it can provide a dose map with higher resolution than using discrete points. |
1. Scope |
1.1 This is a practice for using a cellulose triacetate (CTA) dosimetry system to measure absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. The CTA dosimetry system is classified as a routine dosimetry system. 1.2 The CTA dosimeter is classified as a type II dosimeter on the basis of the complex effect of influence quantities on its response (see ASTM Practice E2628). 1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ASTM E2628 “Practice for Dosimetry in Radiation Processing” for a CTA dosimetry system. It is intended to be read in conjunction with ASTM E2628. 1.4 This practice covers the use of CTA dosimetry systems under the following conditions: 1.4.1 The absorbed dose range is 10 kGy to 300 kGy. 1.4.2 The absorbed-dose rate range is 3 Gy/s to 4×1010 Gy/s (1). 1.4.3 The photon energy range is 0.1 to 50 MeV. 1.4.4 The electron energy range is 0.2 to 50 MeV. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
Historisch
8.8.2013
Historisch
21.3.2012
Historisch
1.6.2012
Historisch
1.3.2013
Historisch
1.3.2013
Historisch
1.6.2013
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-23 (Zahl der Positionen: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.