Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests
Automatische name übersetzung:
Spezifikation für Funkstörungen und Störfestigkeit Messvorrichtung und Verfahren - Teil 4-1: Unsicherheiten, Statistiken und Limit-Modellierung - Unsicherheiten bei standardisierten EMV-Prüfungen
NORM herausgegeben am 23.2.2009
Bezeichnung normen: CISPR/TR 16-4-1-ed.2.0
Ausgabedatum normen: 23.2.2009
SKU: NS-116198
Zahl der Seiten: 117
Gewicht ca.: 382 g (0.84 Pfund)
Land: Internationale technische Norm
Kategorie: Technische Normen CISPR
CISPR/TR 16-4-1:2009 gives guidance on the treatment of uncertainties to those who are involved in the development or modification of CISPR electromagnetic compatibility (EMC) standards. In addition, this part provides useful background information for those who apply the standards and the uncertainty aspects in practice. The objectives of this part are to: a) identify the parameters or sources governing the uncertainty associated with the statement that a given product complies with the requirement specified in a CISPR recommendation. This uncertainty will be called "standards compliance uncertainty"; b) give guidance on the estimation of the magnitude of the standards compliance uncertainty; c) give guidance for the implementation of the standards compliance uncertainty into the compliance criterion of a CISPR standardised compliance test. As such, this part can be considered as a handbook that can be used by standards writers to incorporate and harmonise uncertainty considerations in existing and future CISPR standards. This part also gives guidance to regulatory authorities, accreditation bodies and test engineers to judge the performance quality of an EMC test-laboratory carrying out CISPR standardised compliance tests. The uncertainty considerations given in this part can also be used as guidance when comparing test results (and their uncertainties) obtained by using different alternative test methods. The uncertainty of a compliance test also relates to the probability of occurrence of an electromagnetic interference (EMI) problem in practice. This aspect is recognized and introduced briefly in this part. However, the problem of relating uncertainties of a compliance test to the occurrence of EMI in practice is not considered within the scope of this part. The scope of this part is limited to all the relevant uncertainty considerations of a standardized EMC compliance test. This second edition of CISPR 16-4-1 cancels and replaces the first edition published in 2003, and its Amendments 1 (2004) and 2 (2007). It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. The provisions available for application of uncertainties in the determination of the compliance criterion are explained more generally and a procedure is added for re-testing an approved EUT by another test house.
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-01-08 (Zahl der Positionen: 2 218 384)
© Copyright 2025 NORMSERVIS s.r.o.