Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 3: Calculation procedures regarding adaptive building envelope elements
Name übersetzen
NORM herausgegeben am 1.3.2024
Bezeichnung normen: ČSN EN ISO 52016-3
Zeichen: 730336
Katalog-Nummer: 518571
Ausgabedatum normen: 1.3.2024
SKU: NS-1167265
Zahl der Seiten: 72
Gewicht ca.: 216 g (0.48 Pfund)
Land: Tschechische technische Norm
Kategorie: Technische Normen ČSN
This document specifies procedures for the calculation of the energy needs for heating and cooling, internal temperatures and sensible and latent heat loads of a building according to the hourly calculation methodology in ISO 52016-1. Additions or modifications of the calculations are provided in this document if the building envelope contains one or more adaptive building envelope elements (building envelope elements with adaptive components that are either environmentally or actively controlled as a function of specific conditions). The adaptive building envelope element replaces the transparent building element in the calculation according to ISO 52016-1.
The three types of adaptive building envelope elements covered in this document are:
Environmentally activated control is described for building envelope elements with chromogenic glazing, but can also occur for other types of adaptive building envelope elements. In that case the same approach applies as for environmentally activated chromogenic glazing.
This document is applicable to the assessment of the energy performance of buildings (EPB) (energy performance labels and certificates), including comparison between buildings and checking conformity with minimum energy performance criteria.
It is also applicable to assess the contribution of the adaptive building envelope element to the smart readiness of a building.
In addition, this document provides indicators for the impact of the adaptive building envelope element on the performance of the building compared to a reference building envelope element. It is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase.
This document is not applicable to geometrically complex adaptive building envelope elements that can only be modelled as multiple coupled thermal zones.
NOTE - The background to the selection of adaptive building envelope elements is given in ISO/TR 52016-4
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-04-28 (Zahl der Positionen: 2 197 482)
© Copyright 2025 NORMSERVIS s.r.o.