ČSN EN ISO 80601-2-13-ed.2 (364801)

Medical electrical equipment - Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation

Name übersetzen

NORM herausgegeben am 1.12.2022


Sprache
Realisierung
ZugänglichkeitAUF LAGER
Preis37.60 ohne MWS
37.60

Informationen über die Norm:

Bezeichnung normen: ČSN EN ISO 80601-2-13-ed.2
Zeichen: 364801
Katalog-Nummer: 515658
Ausgabedatum normen: 1.12.2022
SKU: NS-1091116
Zahl der Seiten: 120
Gewicht ca.: 391 g (0.86 Pfund)
Land: Tschechische technische Norm
Kategorie: Technische Normen ČSN

Die Annotation des Normtextes ČSN EN ISO 80601-2-13-ed.2 (364801):

This document is applicable to the basic safety and essential performance of an anaesthetic workstation for administering inhalational anaesthesia whilst continuously attended by a professional operator.

This document specifies particular requirements for a complete anaesthetic workstation and the following anaesthetic workstation components which, although considered as individual devices in their own right, may be utilized, in conjunction with other relevant anaesthetic workstation components, to form an anaesthetic workstation to a given specification:

  • - anaesthetic gas delivery system;
  • - anaesthetic breathing system;
  • - anaesthetic gas scavenging system (AGSS);
  • - anaesthetic vapour delivery system;
  • - anaesthetic ventilator;
  • - monitoring equipment;
  • - alarm system;
  • - protection device.

NOTE 1 - Monitoring equipment, alarm systems and protection devices are summarized in Table AA.1.

An anaesthetic workstation supplied complete and its individual components are considered as ME equipment or ME systems with regard to the general standard.

NOTE 2 - The applicability of this document is indicated in Table AA.2.

This document is also applicable to those accessories intended by their manufacturer to be connected to an anaesthetic workstation where the characteristics of those accessories can affect the basic safety and essential performance of the anaesthetic workstation.

If a clause or subclause is specifically intended to be applicable to anaesthetic workstation components or its accessories only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to an anaesthetic workstation and its individual components including accessories, as relevant.

Hazards inherent in the intended physiological function of an anaesthetic workstation and its individual components including accessories within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1.

NOTE 3 - See also IEC 60601-1:2005+AMD1:2012+AMD2:2020, 4.2.

This document is not applicable to any anaesthetic workstation intended for use with flammable anaesthetic agents, as determined by Annex BB

Empfehlungen:

Aktualisierung der technischen Normen

Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.

Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.




Cookies Cookies

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.

Sie können die Zustimmung verweigern hier.

Hier können Sie Ihre Cookie-Einstellungen nach Ihren Wünschen anpassen.

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können.