Die Norm IEC 60335-2-110-ed.2.0-EXV-RLV 11.7.2024 Ansicht

IEC 60335-2-110-ed.2.0-EXV-RLV

Household and similar electrical appliances - Safety - Part 2-110: Particular requirements for commercial microwave appliances with insertion or contacting applicators

Name übersetzen

NORM herausgegeben am 11.7.2024


Sprache
Realisierung
ZugänglichkeitAUF LAGER
Preis1 380.70 ohne MWS
1 380.70

Informationen über die Norm:

Bezeichnung normen: IEC 60335-2-110-ed.2.0-EXV-RLV
Ausgabedatum normen: 11.7.2024
SKU: NS-1191843
Zahl der Seiten: 286
Gewicht ca.: 889 g (1.96 Pfund)
Land: Internationale technische Norm
Kategorie: Technische Normen IEC

Die Annotation des Normtextes IEC 60335-2-110-ed.2.0-EXV-RLV :

This pack contains IEC 60335-2-110:2024 EXV and IEC 60355-2-110:2024 RLV. IEC 60335-2-110:2024 deals with the safety of microwave appliances intended for commercial use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances. As far as is practicable, this standard deals with the common hazards presented by these types of appliances. Appliances covered by this standard incorporate an open-ended applicator for treatment of the load. They are divided into three types: - with insertion applicator, typically for moisture removal by insertion into holes in floors, walls or ceilings; - with large area contacting applicator, typically for drying of floors, walls or ceilings; - with small area contacting applicator, typically for paint removal and spot-heating. Microwave appliances with insertion applicator, large area contacting applicator or small area contacting applicator are using electromagnetic energy in one or several of the ISM frequency bands between 300 MHz and 30 GHz, for supplying energy to an external load which is heated so that a resulting process of drying, moisture transport which can result in forces due to formation of steam, decomposition or chemical modification, melting, or termination of organisms such as bacteria or fungus occurs. Appliances with insertion applicator and with large area contacting applicator are portable appliances. Appliances with small area contacting applicator are handheld appliances. Appliances that use non-electrical energy are within the scope of this standard. The microwave-related portion is considered motor-operated. The rationales for the microwave barrier and associated leakage tests are described in informative Annex AA. Attention is drawn to the fact that - these appliances can radiate microwave energy outside a restricted area where they are used. The additional requirements specified by national authorities responsible for the protection for non-ionising radiation that the limit of power flux density is 10 W/m2, averaged over any time period of 6 min, outside this restricted area is taken into consideration in this standard; - these appliances are intended to exclusively treat the load in normal operation, i.e. this standard does not apply to appliances or systems employing free space microwave propagation; - for appliances intended to be used in tropical countries, special requirements can be necessary; - in many countries, additional requirements are specified by the national health authorities, and national authorities responsible for the protection of labour and for non-ionising radiation protection. This standard does not apply to - household microwave ovens, including combination microwave ovens (IEC 60335-2-25); - commercial microwave ovens with a cavity door, commercial combination microwave ovens with a cavity door and commercial microwave ovens without a cavity door and with transportation means (IEC 60335-2-90); - industrial microwave heating equipment (IEC 60519-6); - appliances for medical purposes (IEC 60601-1); - appliances and equipment for laboratory use (IEC 61010 series); - appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas); Some of the specifications and tests in this standard are not applicable for other than 2 450 MHz appliances. This second edition cancels and replaces the first edition published in 2013 and Amendment 1:2019. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Subclause 7.1 has been improved in clarity. - Subclauses 19.11.2 and 19.103 have been improved in clarity. - Clause 28 has been modified to add screw requirements. This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.

Empfehlungen:

Aktualisierung der technischen Normen

Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.

Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.




Cookies Cookies

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.

Sie können die Zustimmung verweigern hier.

Hier können Sie Ihre Cookie-Einstellungen nach Ihren Wünschen anpassen.

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können.