Performance standards in building — Performance test for precast concrete floors — Behaviour under non-concentrated load
NORM herausgegeben am 16.12.1993
Designation standards: ISO 9882:1993
Publication date standards: 16.12.1993
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: International technical standard
Kategorie: Technische Normen ISO
Description / Abstract: Defines test procedures for determining the mechanical performance of precast concrete floors made of a single piece, or made up of precast joists (reinforced concrete or precast concrete) completed with filler blocks and concrete poured in situ. The parameters measured are: the maximum load, which does not result in collapse, the instantaneous and deferred deformations under imposed load, and the maximum load which the floor or its constituent precast element can support without collapse during its construction. Applies to floors designed to support loads of less than 5000 N m^-2 and having spans of less than 12 m.