Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Determination of Impurities in Nuclear Grade Uranium Compounds by Inductively Coupled Plasma Mass Spectrometry
Automatische name übersetzung:
Standard Test Methode zur Bestimmung von Verunreinigungen in Nuclear Uran-Verbindungen durch induktiv gekoppelte Plasma-Massenspektrometrie
NORM herausgegeben am 1.6.2010
Bezeichnung normen: ASTM C1287-10
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.6.2010
SKU: NS-10484
Zahl der Seiten: 10
Gewicht ca.: 30 g (0.07 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
impurities, inductively coupled plasmamass spectrometry, uranium, uranium dioxide, uranium hexafluoride, uranyl nitrate solutions, uranium oxide, uranium trioxide, ICP-MS (inductively-coupled plasma-mass spectrometry), Impurities--nuclear materials, Mass spectrometry--nuclear materials/applications, Uranium, Uranium oxide (U3O8), ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology)
1. Scope | ||||||||||||||||||
1.1 This test method covers the determination of 67 elements in uranium dioxide samples and nuclear grade uranium compounds and solutions without matrix separation by inductively coupled plasma mass spectrometry (ICP-MS). The elements are listed in Table 1. These elements can also be determined in uranyl nitrate hexahydrate (UNH), uranium hexafluoride (UF6), triuranium octoxide (U3O8) and uranium trioxide (UO3) if these compounds are treated and converted to the same uranium concentration solution. 1.2 The elements boron, sodium, silicon, phosphorus, potassium, calcium and iron can be determined using different techniques. The analyst's instrumentation will determine which procedure is chosen for the analysis. 1.3 The test method for technetium-99 is given in Annex A1. 1.4 The values stated in SI units are to be regarded as standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. WarningThe ICP-MS is a source of intense ultra-violet radiation from the radio frequency induced plasma. Protection from radio frequency radiation and UV radiation is provided by the instrument under normal operation. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historisch
1.11.2011
Historisch
1.1.2010
Historisch
1.1.2014
Historisch
1.6.2011
Historisch
1.1.2013
Historisch
1.6.2013
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-03 (Zahl der Positionen: 2 209 203)
© Copyright 2024 NORMSERVIS s.r.o.