Standard Test Method for Analysis of Austenitic Stainless Steel by Spark Atomic Emission Spectrometry
Name übersetzen
NORM herausgegeben am 15.8.2022
Bezeichnung normen: ASTM E1086-22
Ausgabedatum normen: 15.8.2022
SKU: NS-1071065
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
austenitic stainless steel, spark atomic emission, spectrometric analysis, spectrometry,, ICS Number Code 77.040.30 (Chemical analysis of metals),77.140.20 (Steels of high quality)
Significance and Use | |
5.1?The chemical composition of stainless steels must be determined accurately to ensure the desired metallurgical properties. This test method is suitable for manufacturing control and inspection testing. |
|
1. Scope | |
1.1?This test method Element |
Composition Range, % |
Chromium |
17.0 to 23.0 |
Nickel |
7.5 to 13.0 |
Molybdenum |
0.01 to 3.0 |
Manganese |
0.01 to 2.0 |
Silicon |
0.01 to 0.90 |
Copper |
0.01 to 0.30 |
Carbon |
0.005 to 0.25 |
Phosphorus |
0.003 to 0.15 |
Sulfur |
0.003 to 0.065 |
1.2?This test method is designed for the analysis of chill-cast disks or inspection testing of stainless steel samples that have a flat surface of at least 13 mm (0.5 in.) in diameter. The samples must be sufficiently massive to prevent overheating during the discharge and of a similar metallurgical condition and composition as the reference materials.
1.3?One or more of the reference materials must closely approximate the composition of the specimen. The technique of analyzing reference materials with unknowns and performing the indicated mathematical corrections (typically referred to as type standardization) may also be used to correct for interference effects and to compensate for errors resulting from instrument drift. A variety of such systems are commonly used. Any of these that will achieve analytical accuracy equivalent to that reported for this test method are acceptable.
1.4?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM MNL 7 |
Manual on Presentation of Data and Control Chart Analysis ASTM Manual Series, ASTM International, 8th edition, 2010. |
Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials (Includes all amendments and changes 7/17/2023). |
|
Standard Practice for Verification and Use of Control Charts in Spectrochemical Analysis (Withdrawn 2019) |
|
Standard Practice for Establishing and Controlling Spark Atomic Emission Spectrochemical Analytical Curves |
|
Standard Practice for Sampling Steel and Iron for Determination of Chemical Composition |
|
Standard Practice for Using Controlled Atmospheres in Atomic Emission Spectrometry |
|
Practice for Interlaboratory Testing of Spectrochemical Methods of Analysis (Withdrawn 1997) |