Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure and Temperature Differences Across the Specimen
Automatische name übersetzung:
Standard Test Methode zur Bestimmung der Rate des Luftverluste durch Außenfenster, Fassaden und Türen unter bestimmten Druck- und Temperaturunterschiede über die Probe
NORM herausgegeben am 1.9.2008
Bezeichnung normen: ASTM E1424-91(2008)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.9.2008
SKU: NS-41718
Zahl der Seiten: 7
Gewicht ca.: 21 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
air leakage, curtain walls, differential temperature, doors, fenestration, energy analysis, laboratory method, static pressure chamber, test method, testing, windows, Air leakage testing--building materials/constructions, Building envelopes, Curtain walls, Differential temperature, Doors/door assemblies, Energy analysis, Exterior doors, Exterior windows, Windows/window assemblies, ICS Number Code 91.060.50 (Doors and windows)
Significance and Use | ||||||
The exterior building envelope and its components (for example, windows and doors) separate the interior conditioned spaces from exterior environmental factors such as heat, cold, rain, wind, noise dust, etc. Building materials and components can expand or contract to varying degrees, depending on seasonal and diurnal exterior ambient air temperatures. Fluctuations in the ambient air temperatures can alter the sealing characteristics of windows, curtain walls, and doors by changing weather seal compression ratios. Thermal expansion or contraction of framing materials coupled with thermal blowing due to temperature gradients through the product, and alterations in the effective leakage areas due to weather seal shrinkage and compression set, can also significantly alter the air leakage rates of these products in field service applications. Air leakage tests performed using Test Method E 283 (a laboratory air leakage test performed at ambient temperature conditions) will not account accurately for changes in air leakage rates that may occur from dimensional changes in fenestration systems, materials, and components. It is recommended that test specifiers consult the manufacturer for recommended test temperature extremes. This procedure provides a means for evaluating air leakage rates of fenestration systems under various temperature and pressure conditions and air flow directions. It is also applicable for use in evaluating the efficiency of weather sealing products in fenestration systems. All air flow rates are converted to standard conditions to provide a means of comparison between measurements made at different ambient air temperature and pressure conditions. Air leakage rates are sometimes used for comparison purposes. Such comparisons may not be valid unless the components being tested and compared are of essentially the same size, configuration, and design. |
||||||
1. Scope | ||||||
1.1 This test method provides a standard laboratory procedure for determining the air leakage rates of exterior windows, curtain walls, and doors under specified differential air temperature and pressure conditions across the specimen. 1.2 Specified temperature and pressure conditions are representative of those that may be encountered at the exterior thermal envelope of buildings, excluding the effects of heat buildup due to solar radiation. 1.3 This laboratory procedure is applicable to exterior windows, curtain walls, and doors and is intended to measure only such leakage associated with the assembly and not the installation; however, the test method can be adapted for the latter purpose. 1.4 This is a laboratory procedure for testing at differential temperature conditions. Persons interested in a laboratory test at ambient conditions should reference Test Method E 283. Persons interested in a field test on installed windows and doors should reference Test Method E 783. 1.5 Persons using this procedure should be knowledgeable in the areas of heat transfer, fluid mechanics, and instrumentation practices, and shall have a general understanding of fenestration products and components. 1.6 The values stated in SI units are to be regarded as standard. The inch-pound units given in parenthesis are provided for information only. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7. |
||||||
2. Referenced Documents | ||||||
|
Historisch
1.3.2011
Historisch
1.10.2012
Historisch
15.4.2014
Historisch
1.2.2014
Historisch
1.5.2014
Historisch
1.5.2014
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-26 (Zahl der Positionen: 2 209 597)
© Copyright 2024 NORMSERVIS s.r.o.