Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Reference Radiographs for Examination of Aluminum Fusion Welds
Automatische name übersetzung:
Standard-Referenzröntgenbilderfür die Prüfung von Aluminiumschmelzschweißnähten
NORM herausgegeben am 1.9.2015
Bezeichnung normen: ASTM E1648-15
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.9.2015
SKU: NS-615831
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
aluminum, discontinuities, radiograph density, reference radiographs, welds, X-ray ,, ICS Number Code 25.160.40 (Welding joints and welds)
Significance and Use | ||||||||||||||
4.1 Use of these reference radiographs requires agreement between the using parties as to the acceptable level of each discontinuity type. Illustrations are provided for welds in 0.125-in. (3.2-mm) thick material and 0.50-in. (12.7-mm) thick material. These illustrations are intended to be representative of base material thicknesses up to 0.75 in. (19 mm). Use of these reference radiographs is not intended to be restricted to the specific energy level or the absolute thickness limits that are illustrated. These reference radiographs may be used, where there is no other applicable document, for other energy levels or thicknesses, or both, for which agreement has been reached between the purchaser and the manufacturer. Standard reference radiographs should be used in accordance with contractual specifications. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 These reference radiographs illustrate various types and severity levels of discontinuities in aluminum fusion welds that may be revealed by radiographic examination. These reference radiographs do not specify the acceptable level of these discontinuities, rather they provide a visual reference for communicating the acceptable level. Note 1: The reference radiographs consist of a set of eight
plates (81/2 by 11 in. (22 by 28 cm)),
covering base material up to and including 0.75 in. (19 mm) in
thickness.
1.2 These reference radiographs are based on two nominal weld thicknesses in wrought aluminum products and are applicable to the thickness ranges shown in Table 1. The welds were produced using base material plates of 6061 and 5083 alloys and 5356 and 4043 gas metal-arc (GMA) electrodes. These reference radiographs are intended for use in evaluating radiographs of welds in wrought aluminum products. They are not recommended for use with repair welds in cast materials; however, they are appropriate for use with assembly or fabrication welds. Reference radiographs for aluminum and magnesium castings are available in Reference Radiographs E155 and E505. 1.3 The adjunct contains illustrations of representative graded and ungraded discontinuities. Table 2 lists the discontinuity types and severities illustrated for each thickness of base material. Each of the graded discontinuity types has five severity levels, 1 through 5, in order of increasing severity. The ungraded discontinuities are included for informational purposes. 1.4 From time to time, there may be minor changes to the process for manufacturing of the reference radiograph adjunct materials. These changes could include changes in the films or processing chemicals used, changes in the dies or printing for the cardboard mats, etc.; however, in all cases, these changes are reviewed by the Illustration Monitoring Subcommittee and all reference radiographs are reviewed against a fixed prototype image to ensure that there are no changes to the acceptance level represented by the reference radiographs. Therefore, the adjunct reference radiographs remain valid for use with this standard regardless of the date of production or the revision level of the text standard. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Historisch
1.10.2014
Historisch
1.5.2011
Historisch
1.9.2015
Historisch
1.1.2013
Historisch
1.11.2014
Historisch
1.3.2011
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-13 (Zahl der Positionen: 2 215 533)
© Copyright 2024 NORMSERVIS s.r.o.