Standard Practice for Verification of Constant Amplitude Dynamic Forces in an Axial Fatigue Testing System
Automatische name übersetzung:
Standard Praxis zur Überprüfung der konstante Amplitude Dynamic Forces in einer Axial Fatigue Testing System
NORM herausgegeben am 1.5.2014
Bezeichnung normen: ASTM E467-08(2014)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.5.2014
SKU: NS-46895
Zahl der Seiten: 11
Gewicht ca.: 33 g (0.07 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
ICS Number Code 77.040.10 (Mechanical testing of metals)
Significance and Use | ||||||||||||||
4.1 It is well understood how to measure the forces applied to a specimen under static conditions. Practices E4 details the required process for verifying the static force measurement capabilities of testing machines. During dynamic operation however, additional errors may manifest themselves in a testing machine. Further verification is necessary to confirm the dynamic force measurement capabilities of testing machines. Note 1: The static machine verification accomplished by
Practices E4 simply
establishes the reference. Indicated forces measured from the force
cell are compared with the dynamometer conditioned forces
statically for confirmation and then dynamically for dynamic
verification of the fatigue testing system's force
output.
Note 2: The dynamic accuracy of the force cell's output will
not always meet the accuracy requirement of this standard without
correction. Dynamic correction to the force cell output can be
applied provided that verification is performed after the
correction has been applied.
Note 3: Overall test accuracy is a combination of measurement
accuracy and control accuracy. This practice provides methods to
evaluate either or both. As control accuracy is dependent on many
more variables than measurement accuracy it is imperative that the
test operator utilize appropriate measurement tools to confirm that
the testing machine’s control behavior is consistent between
verification activities and actual testing activities.
4.2 Dynamic errors are primarily span dependent, not level dependent. That is, the error for a particular force endlevel during dynamic operation is dependent on the immediately preceding force endlevel. Larger spans imply larger absolute errors for the same force endlevel. 4.3 Due to the many test machine factors that influence dynamic force accuracy, verification is recommended for every new combination of potential error producing factors. Primary factors are specimen design, machine configuration, test frequency, and loading span. Clearly, performing a full verification for each configuration is often impractical. To address this problem, dynamic verification is taken in two parts. 4.3.1 First, one or more full verifications are performed at least annually. The main body of this practice describes that procedure. This provides the most accurate estimate of dynamic errors, as it will account for electronic as well as acceleration-induced sources of error. 4.3.2 The second part, described in Annex A1, is a simplified verification procedure. It provides a simplified method of estimating acceleration-induced errors only. This procedure is to be used for common configuration changes (that is, specimen/grip/crosshead height changes). 4.4 Dynamic verification of the fatigue system is recommended over the entire range of force and frequency over which the planned fatigue test series is to be performed. Endlevels are limited to the machine's verified static force as defined by the current static force verification when tested in accordance with Practices E4. Note 4: There is uncertainty as to whether or not the
vibration in a frame will be different when operating in
compression as opposed to tension. As a consequence, this practice
recommends performing verifications at maximum tension and maximum
compression endlevels. The total span does not need to be between
those two levels, but can be performed as two tests.
Note 5: Primary electronic characteristics affecting dynamic
measurement accuracy are noise and bandwidth. Excessive noise is
generally the dominant effect at the minimum test frequency.
Insufficient bandwidth-induced errors are generally most
significant at the maximum test frequency.
|
||||||||||||||
1. Scope | ||||||||||||||
1.1 This practice covers procedures for the dynamic verification of cyclic force amplitude control or measurement accuracy during constant amplitude testing in an axial fatigue testing system. It is based on the premise that force verification can be done with the use of a strain gaged elastic element. Use of this practice gives assurance that the accuracies of forces applied by the machine or dynamic force readings from the test machine, at the time of the test, after any user applied correction factors, fall within the limits recommended in Section 9. It does not address static accuracy which must first be addressed using Practices E4 or equivalent. 1.2 Verification is specific to a particular test machine configuration and specimen. This standard is recommended to be used for each configuration of testing machine and specimen. Where dynamic correction factors are to be applied to test machine force readings in order to meet the accuracy recommended in Section 9, the verification is also specific to the correction process used. Finally, if the correction process is triggered or performed by a person, or both, then the verification is specific to that individual as well. 1.3 It is recognized that performance of a full verification for each configuration of testing machine and specimen configuration could be prohibitively time consuming and/or expensive. Annex A1 provides methods for estimating the dynamic accuracy impact of test machine and specimen configuration changes that may occur between full verifications. Where test machine dynamic accuracy is influenced by a person, estimating the dynamic accuracy impact of all individuals involved in the correction process is recommended. This practice does not specify how that assessment will be done due to the strong dependence on owner/operators of the test machine. 1.4 This practice is intended to be used periodically. Consistent results between verifications is expected. Failure to obtain consistent results between verifications using the same machine configuration implies uncertain accuracy for dynamic tests performed during that time period. 1.5 This practice addresses the accuracy of the testing machine's force control or indicated forces, or both, as compared to a dynamometer's indicated dynamic forces. Force control verification is only applicable for test systems that have some form of indicated force peak/valley monitoring or amplitude control. For the purposes of this verification, the dynamometer's indicated dynamic forces will be considered the true forces. Phase lag between dynamometer and force transducer indicated forces is not within the scope of this practice. 1.6 The results of either the Annex A1 calculation or the full experimental verification must be reported per Section 10 of this standard. 1.7 This practice provides no assurance that the shape of the actual waveform conforms to the intended waveform within any specified tolerance. 1.8 This standard is principally focused at room temperature operation. It is believed there are additional issues that must be addressed when testing at high temperatures. At the present time, this standard practice must be viewed as only a partial solution for high temperature testing. 1.9 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard. 1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Historisch
1.9.2008
Historisch
1.6.2012
Historisch
1.1.2000
Historisch
15.10.2013
Historisch
1.10.2010
Historisch
1.7.2013
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-04 (Zahl der Positionen: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.