Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Practice for Determining the Field Performance of Commercial Kitchen Demand Control Ventilation Systems
Automatische name übersetzung:
Standard Praxis zur Bestimmung der Feldleistung von Grossküchenbedarfsregelung Lüftungssysteme
NORM herausgegeben am 1.6.2013
Bezeichnung normen: ASTM F2976-13
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.6.2013
SKU: NS-54807
Zahl der Seiten: 6
Gewicht ca.: 18 g (0.04 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
commercial kitchen ventilation, demand control ventilation, variable speed exhaust systems, ICS Number Code 91.140.30 (Ventilation and air-conditioning systems)
Significance and Use | ||||
5.1 Fan Energy—This standard practice determines the fan energy requirements for a constant speed and demand controlled kitchen ventilation system and estimates the savings. It can be used to compare systems' fan savings potential. 5.2 Heating and Cooling Energy—This standard practice determines the heating and cooling energy requirements for a constant speed and demand controlled kitchen ventilation system and estimates the savings. It can be used to compare systems' heating and cooling savings potential. |
||||
1. Scope | ||||
1.1 This Standard Practice determines the energy savings potential of Commercial Kitchen Demand Control Ventilation (CKDCV) systems by outlining a procedure to measure system performance. 1.1.1 Fan energy savings potential of a Commercial Kitchen Demand Control Ventilation system will be determined. 1.1.2 Thermal energy savings potential of a Commercial Kitchen Demand Control Ventilation system will be determined. 1.2 This Standard Practice applies to commercial kitchen exhaust and supply demand control ventilation system in the following foodservice establishments: Casino hotel foodservice facilities, commercial cafeterias, full service restaurant, hotel foodservice facility, quick service restaurant, school cafeteria, supermarket, health care foodservice facility. See 1.3 This CKDCV field test protocol does not apply to other demand control ventilation applications such as building heating, ventilation, and air-conditioning (HVAC) applications or laboratory applications. 1.4 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||
2. Referenced Documents | ||||
|
Historisch
1.8.2011
Historisch
1.4.2012
Historisch
1.8.2013
Historisch
1.5.2014
Historisch
15.1.2010
Historisch
1.10.2013
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-03 (Zahl der Positionen: 2 209 203)
© Copyright 2024 NORMSERVIS s.r.o.